Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros

Base de datos
Tipo del documento
Intervalo de año
1.
BMJ Case Rep ; 15(4)2022 Apr 21.
Artículo en Inglés | MEDLINE | ID: covidwho-1807347

RESUMEN

We report a 4-year delay in diagnosing a combined carotid arterial and jugular venous styloid compression. The symptoms, which included dull neck pain, dizziness, intermittent diplopia, tinnitus, severe incapacitating right side headache and eye bloating, were challenging and wrongly attributed initially to various facial neuralgias. The patient presented during COVID-19 pandemic and was labelled as 'carotidynia' first and later as a transient perivascular inflammation of carotid artery syndrome. Combined targeted duplex ultrasonography and CT angiography with 3D reconstruction revealed a long styloid process and its tendinous-ligamentous attachments, injuring the internal carotid artery. Moreover, there was substantial internal jugular vein compression on a long C1 transverse process with a nutcracker syndrome. Release of the tendinous portion of the long styloid process and repair of the carotid artery pseudoaneurysm ended the patient's complaints and allowed him to have a better quality of life.


Asunto(s)
Aneurisma Falso , COVID-19 , Aneurisma Falso/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Humanos , Venas Yugulares/diagnóstico por imagen , Masculino , Osificación Heterotópica , Pandemias , Calidad de Vida , Síndrome , Hueso Temporal/anomalías
2.
BMJ Case Rep ; 14(8)2021 Aug 25.
Artículo en Inglés | MEDLINE | ID: covidwho-1373951

RESUMEN

We present a 54-year-old Caucasian woman, who presented with acute symptomatic type B aortic dissection with deteriorating renal function. She was a known smoker with a 2-year history of dysphagia. CT angiography documented the artery of lusoria arising from the mid-thoracic aorta, aneurysmal dilation of her descending aorta, and kinetic and static flaps around her visceral ostia. The patient was managed by staged hybrid single lumen reconstruction and bilateral subclavian to carotid transpositions. During follow-up, there was no aortic rupture or retrograde type A dissection. There were no renal, visceral, cardiac, pulmonary or spinal complications. The patient went off her antihypertensive medication with a normal estimated glomerular filtration rate and accelerated aortic modulation.


Asunto(s)
Aneurisma de la Aorta Abdominal , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Femenino , Humanos , Persona de Mediana Edad , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía
3.
Eur Heart J Case Rep ; 4(6): 1-7, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1028929

RESUMEN

BACKGROUND: Cardiovascular toxicity as a consequence of nicotine from conventional tobacco cigarette smoking is well documented. However, little is known about the cardiovascular consequences of nicotine e-vaping. We review the literature and report a case series of three cases of major adverse cardiovascular clinical effects post nicotine e-vaping. CASE SUMMARY: Three patients with known peripheral arterial disease who switched from heavy cigarette smoking consumption to a high-intensity dose of nicotine e-vaping all developed further arterial complications within 6-30 months. DISCUSSION: With the recent epidemic of e-vaping in young individuals and the national outbreak of e-vaping use-associated lung injury (EVALI), the dangers of e-vaping are now coming to light. The pulmonary effects are now well described, and this paper highlights three new cases of cardiovascular toxicity associated with e-vaping. The potential role of nicotine e-vaping and the risk of coronavirus disease-2019 (COVID-19) will also be discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA